1799 Results found

Level Measurement Screening Debris Container

Level Measurement Screening Debris Container Wastewater Treatment Plant - Intake Area Application Screenings container, 2.5 x 2.5 x 4.0 m (w x h x d) Medium: solid mixture Bulk cone with undefined angle Ex-Zone 1 Definition of tasks Level detection inscreenings container for overflow monitoring and

Contactless Flow Measurement

Contactless Flow Measurement Wastewater Treatment Plant - Intake Area Application Concrete channel, width 1.2 m Partially filled Measurement point upstream of screen and grit trap High sedimentation loads Definition of tasks Intake measurement as control measure to avoid WWTP flood Contactless measu

Flow Measurement in Service Reservoir

Flow Measurement in Service Reservoir Flowing Waters - Irrigation & Drainage Systems Application Special profile, approx. 2.5 x 2.0 m (h x w) Partially filled Channel made of natural stone and concrete High flow dynamics Definition of tasks Detection of readings of a service reservoir intake for vol

Contactless Flow Measurement on Fish Ladder

Contactless Flow Measurement on Fish Ladder Flowing Waters - Special Constructions Application Concrete intake channel 3.0 x 2.0 m (w x h) Partially filled Gravel bed Definition of tasks Flow measurement to ensure a minimum water volume required for the fish ladder No sensors can be installed on the

Volume Measurement Overhead Tank

Volume Measurement Overhead Tank Water Supply - Drinking Water Application Pipe with 0.25 m diameter, made of cast iron Fully filled Overhead tank featuring one single pipeline and flow in both directions Definition of tasks Comparison between water volumes consumed within the supply network during

Contaminated Groundwater Flow Measurement

Contaminated Groundwater Flow Measurement Flowing Waters - Irrigation & Drainage Systems Application Trapezoid channel 1.5 x 0.5 m (w x h) Partially filled Concrete channel bottom, embankment reinforced with water engineered stones Remote measurement place Definition of tasks Flow measurement in par

Dam Intake Measurement

Dam Intake Measurement Flowing Waters - Power Plants Application Rectangular channel 1.80 x 3.00 m (h x w), partially concrete, partially dry-stone walls Partially filled Rainwater and surface water Short calming section Manual detection of flow rates (level reading and Q/h-table) destroyed after fl

Dam Intake Measurement

Dam Intake Measurement Flowing Waters - Power Plants Application Rectangular channel 1.80 x 3.00 m (h x w), partially concrete, partially dry-stone walls Partially filled Rainwater and surface water Short calming section Manual detection of flow rates (level reading and Q/h-table) destroyed after fl

Flow Measurement to Ensure Minimum Discharge

Flow Measurement to Ensure Minimum Discharge Flowing Waters - Irrigation & Drainage Systems Application Trapezoid channel 7.0 x 3.0 m (w x h) Partially filled Concrete channel bottom, embankment reinforced with water engineered stones Upstream adjustable water separator Definition of tasks Flow meas

Detection of Nighttime Volume

Detection of Nighttime Volume Water Supply - Drinking Water Application Pipe with 0.1 m diameter Fully filled Low water volumes of approx. 3 l/s Definition of tasks Detection of problematic low quantities from a drinking water overhead tank during nighttimes Replaces the EMF not working properly due

Hello
We are glad to have you here! For any question regarding water or digitisation we are happy to answer you call or your email message.
Team NIVUS